The EVO/Passlock module will read an analog voltage from the Passlock sensor. Based on an internal reference, the EVO/Passlock module will determine if the measured voltage is open, shorted to ground, a valid code, or a tamper code. there are 10 possible valid code combinations. The EVO/Passlock module will only accept the last learned valid code.
• | The ignition switch is ON. |
• | The Passlock sensor signal input is less than 0.4 volts for 1 second after turning the ignition switch to the crank position. |
• | The vehicle will not run if the fault occurs before the vehicle is started. The security telltale will flash for 10 minutes and then turn ON steady. |
• | If the vehicle is running when the fault occurs, the EVO/Passlock module will be in the fail enabled mode allowing the vehicle to start and run. The security telltale will be ON. |
• | The DTC will clear after an ignition cycle has occurred without the fault. |
• | EVO/Passlock module history codes will be cleared after 100 ignition cycles with no current codes active. |
• | Using a scan tool |
• | When replacing the Passlock sensor, all the sensor components; the lock, the sensor, the filter, and the harness, are included as a replacement part and must be replaced. |
• | Use the scan tool in order to test the Passlock data voltage and the Passlock code. |
• | Perform a visual inspection of the wiring and the connectors. |
• | Inspect the Passlock sensor harness for an intermittent or poor connections (including the in-line connector). Refer to Intermittents and Poor Connections . |
The numbers below refer to the numbers on the diagnostic table.
This step tests for a short to ground in CKT 1836.
This step tests for the 5 volt reference in the EVO/Passlock module in order to determine if the module or the Passlock sensor need to be replaced.
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the VTD Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||||||||||||||
2 |
Is the resistance within the specified value? | (OL) infinite | Go to Step 3 | Go to Step 6 | ||||||||||||||||||||||||
3 |
Does the scan tool read "Passlock code open"? | -- | Go to Step 4 | Go to Step 5 | ||||||||||||||||||||||||
4 | Remove the jumper and Replace the Passlock sensor in the electronic column lock module assembly.
Is the repair complete? | -- | Go to Step 7 | -- | ||||||||||||||||||||||||
5 |
Is the repair complete? | -- | Go to Step 7 | -- | ||||||||||||||||||||||||
6 | Repair the short to ground in CKT 1836. Is the repair complete? | -- | -- | |||||||||||||||||||||||||
7 |
Is the repair complete? | -- | -- |