The VCM monitors the performance of the EVAP system by applying a predetermined level of vacuum to the EVAP system and monitors the vacuum decay rate. The VCM sets this DTC if the vacuum decay rate is greater than a predetermined value. The VCM monitors the amount of vacuum and the amount of pressure in the EVAP system by monitoring the Fuel Tank Pressure sensor. For this DTC the VCM turns ON both the EVAP Purge Valve and the EVAP Vent Valve when the Conditions for Running the DTC are met. This applies an engine vacuum to a closed EVAP system. The VCM turns OFF both the EVAP Purge Valve and the EVAP Vent Valve when the system reaches a correct amount of vacuum. The EVAP system should quickly RELEASE the vacuum in the EVAP system with the EVAP Purge Valve OFF and the EVAP Vent Valve OFF (open). This test indicates a blocked or restricted EVAP Vent Valve or path if the EVAP system fails to release the vacuum quickly enough.
• | No active MAP sensor DTCs |
• | No active TP sensor DTCs |
• | No active VS sensor DTCs |
• | No active O2 sensor DTCs |
• | No active ECT sensor DTCs |
• | No active IAT sensor DTCs |
• | DTC P0125 not active |
• | The fuel level is greater that 12.5% but less than 87% |
• | The system voltage is between 10 and 17 volts |
• | The ECT is between 4°C and 30°C (39°F to 86°F) |
• | The IAT is between 4°C and 30°C (39°F to 86°F) |
• | The cold start temperature difference (ECT minus IAT) is less than |
1.5°C when the IAT is greater than the ECT or |
8°C when the ECT is greater than the IAT |
• | The BARO is greater than 72 kPa |
• | The change in fuel tank vacuum is less than 0.6 in. of H2O, or the change in fuel level is less than 8% |
• | The fuel tank vacuum level remains above a calibrated value for a specified number of seconds |
The VCM fails to detect a drop in the EVAP system vacuum over a calibrated number of seconds with the vent solenoid open.
• | The VCM illuminates the MIL during the first key cycle in which the DTC sets. |
• | The VCM stores the conditions that were present when the DTC sets as a Freeze Frame and Fail Records data. |
• | The control module turns OFF the MIL after 3 consecutive drive trips when the test has run and passed. |
• | A history DTC will clear if no fault conditions have been detected for 40 warm-up cycles. A warm-up cycle occurs when the coolant temperature has risen 22°C (40°F) from the startup coolant temperature and the engine coolant reaches a temperature that is more than 70°C (158°F) during the same ignition cycle. |
• | Use a scan tool in order to clear the DTCs. |
Important: An accurate indication of fuel level is required for the VCM to properly Pass or Fail this DTC. Always diagnose fuel level sensor DTCs before performing this DTCs diagnostic table. Always check for fuel level sensor DTCs stored in History.
Check for the following conditions:
• | A loose, missing, damaged, incorrect or improperly installed fuel cap |
• | Missing or damaged O-rings at EVAP canister fuel vapor and purge line fittings |
• | A cracked or punctured EVAP canister |
• | Incorrectly routed or defective EVAP system vacuum and vapor lines |
• | A damaged or disconnected EVAP purge line, vent hose or fuel tank vapor line |
• | A stuck closed EVAP Vent Valve |
• | A restricted or stuck closed fuel tank rollover valve |
• | A poor connection at the VCM: Inspect the harness connectors for the following conditions: |
- | Backed out terminals |
- | Improper mating |
- | Broken locks |
- | Improperly formed or damaged terminals |
- | poor terminal to wire connection |
• | A damaged harness: Inspect the wiring harness to the EVAP vent solenoid, EVAP purge solenoid and the fuel tank pressure sensor for an intermittent, open or short circuit |
• | A kinked, pinched or plugged EVAP purge, or fuel tank vapor line. Verify that the lines are not restricted |
Refer to EVAP System Cleaning before starting repairs.
Reviewing the Fail Records vehicle mileage since the diagnostic test last failed may help determine how often the condition that caused the DTC to be set occurs. This may assist in diagnosing the condition.
Number(s) below refer to the step number(s) on the Diagnostic Table.
If the vacuum stored in the EVAP system is quickly released then an intermittent system restriction or failure of the EVAP Vent Valve or the EVAP Fuel Tank Pressure Sensor may have occurred.
Checking the vapor canister and the EVAP Vent Valve for restriction.
An EVAP Pressure sensor that does not correctly respond to pressure (or vacuum) will cause this DTC to set. The EVAP Pressure Sensor monitors a range from 7.5 in. H2O of pressure to -17.5 in. H2O of pressure (vacuum). In order to test the EVAP Pressure sensor for pressure response SEAL the system with the scan tool and use the EVAP pressure/purge diagnostic cart to apply pressure to the system. Compare the pressure gauge (in. H2O) on the diagnostic cart to the EVAP Pressure sensor reading on the scan tool.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Important: : Before clearing the DTCs, use the scan tool Capture Info to save the Freeze Frame and Failure Records for reference. The control module's data is deleted once the Clear Info function is used. Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
2 | Inspect the EVAP system for the following conditions:
Repair the EVAP system if needed. Was a repair made to the EVAP system? | -- | ||
3 | Are DTCs P0452 or P0453 also set? | -- | ||
Does the EVAP Fuel Tank Pressure sensor quickly drop to near 0 in H2O when 0% EVAP Purge is commanded and the EVAP Vent Valve is opened? | -8 in H2O | Go to Diagnostic Aids. | ||
Does the vacuum drop from the specified value when the EVAP Vent Valve is opened? | 5 in Hg | |||
6 |
Does the vacuum drop from the specified value when the vent line is unplugged? | 5 in Hg | ||
7 |
Was the EVAP Vent line replaced? | -- | ||
8 |
Was the fuel tank vapor line replaced? | -- | ||
Important: The following steps require the EVAP pressure/purge diagnostic station J 41413. Always zero the EVAP Pressure and Vacuum (in H2O) gauges on the EVAP pressure/purge diagnostic station before proceeding with diagnosis.
Do both values indicate the same amount of vacuum in the EVAP system to within the range specified? | + / - 2 in H2O | |||
10 |
| -- | ||
11 | Check for a short to ground on the EVAP Vent Valve Driver circuit. Repair circuit as necessary. Was a problem found? | -- | ||
12 | Replace the EVAP Vent Valve. Refer to Evaporative Emission Vent Valve Replacement . Is the replacement complete? | -- | -- | |
13 | Replace the EVAP Vapor Canister. Refer to Evaporative Emission Canister Replacement . Is the replacement complete? | -- | -- | |
14 | Replace the EVAP Fuel Tank Pressure sensor. Refer to Fuel Tank Pressure Sensor Replacement . Is the replacement complete? | -- | -- | |
15 |
Is the action complete? | -- | -- | |
16 |
Does the Scan Tool indicate the diagnostic Passed? | -- | -- | |
17 | Does the Scan Tool display any additional undiagnosed DTCs? | -- | Go to the applicable DTC table | System OK |