TFP Valve Position Switch Resistance Check
Step
| Action
| Value(s)
| Yes
| No
|
Important: Whenever the transmission 20-way connector is disconnected, and the
engine is running, multiple DTCs set. Clear any codes after finishing the
procedure.
|
1
|
- Install the J 39775
jumper harness on the transmission side of the 20-way connector.
- Using the J 39200
digital multimeter (DMM) and the J 35616
connector test adapter kit, measure the resistance from
terminal N to the transmission case.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 3
|
Go to Step 2
|
2
|
- Disconnect the automatic transmission (A/T) wiring harness assembly
from the TFP manual valve position switch.
- Measure the resistance from terminal A of the TFP manual
valve position switch to the switch housing.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 15
|
Go to Step 16
|
3
| Measure
the resistance from terminal R to the transmission case.
Is the resistance greater than the indicated value?
| 50 kohms
|
Go to Step 5
|
Go to Step 4
|
4
|
- Disconnect the A/T wiring harness assembly from the TFP manual
valve position switch.
- Measure the resistance from terminal B of the TFP manual
valve position switch to the switch housing.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 15
|
Go to Step 16
|
5
| Measure
the resistance from terminal P to the transmission case.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 7
|
Go to Step 6
|
6
|
- Disconnect the A/T wiring harness assembly from the TFP manual
valve position switch.
- Measure the resistance from terminal C of the TFP manual
valve position switch to the switch housing.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 15
|
Go to Step 16
|
7
|
- Start the engine and let the engine idle.
- Set the parking brake.
- Place the gear selector in DRIVE (D4).
- Measure the resistance from terminal R to the transmission
case.
Is the resistance less than the indicated value?
| 200ohms
|
Go to Step 8
|
Go to Step
14
|
8
|
- Place the gear selector in DRIVE (D4).
- Measure the resistance from terminal P to the transmission
case.
Is the resistance less than the value indicated?
| 200ohms
|
Go to Step 9
|
Go to Step
14
|
9
|
- Place the selector in LOW (D1).
- Measure the resistance from terminal N to the transmission
case.
Is the resistance less than the value indicated?
| 200ohms
|
Go to Step 10
|
Go to Step
14
|
10
|
- Place the gear selector in LOW (D1).
- Measure the resistance from terminal P to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 11
|
Go to Step 16
|
11
|
- Place the gear selector in REVERSE (R).
- Measure the resistance from terminal N to the transmission
case.
Is the resistance less than the value indicated?
| 200ohms
|
Go to Step 12
|
Go to Step
16
|
12
|
- Place the transmission in REVERSE (R).
- Measure the resistance from terminal P to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kohms
|
Go to Step 13
|
Go to Step 16
|
13
|
- Place the gear selector in Manual THIRD (D3).
- Measure the resistance from terminal R to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kohms
| System OK
|
Go to Step 16
|
14
|
- Disconnect the A/T wiring harness from the TFP manual valve position
switch.
- Inspect CKT 1224 (PNK), 1225 (DK BLU),
and 1226 (RED) of the A/T wiring harness assembly for an open circuit.
Was a condition found?
| --
|
Go to Step
15
|
Go to Step
16
|
15
| Replace the A/T wiring harness
assembly.
Refer to Wiring Harness Replacement.
Is the replacement complete?
| --
|
Go to Step
1
| --
|
16
|
- Replace the TFP manual valve position switch.
Refer to
Control Valve Body Replacement
.
- Inspect the A/T wiring harness assembly.
Is the replacement of the TFP manual valve position switch complete?
| --
|
Go to Step 1
| --
|