The heated oxygen sensor (HO2S) is a sensor designed to create a voltage relative to the oxygen content in the engine exhaust stream. The control module supplies the HO2S with signal high and low circuits. Ignition voltage and ground are supplied to the HO2S heater by independent circuits. The oxygen content of the exhaust indicates when the engine is operating lean or rich. When the HO2S detects that the engine is operating rich, the signal voltage is high, and decreases the signal voltage as the engine runs leaner. This oscillation above and below the bias voltage, sometimes referred to as activity or switching, can be monitored with the HO2S signal voltage.
The HO2S contains a heater that is necessary in order to quickly warm the sensor to operating temperature. The heater also maintains the operating temperature during extended idle conditions. The HO2S needs to be at a high temperature in order to produce a voltage. When the HO2S reaches operating temperature, the control module monitors the HO2S bias, or reference, voltage. It also monitors the HO2S signal voltage for Closed Loop fuel control. During normal Closed Loop fuel control operation, the control module will add fuel, or enrich the mixture, when the HO2S detects a lean exhaust content. The control module will subtract fuel, or "lean-out" the mixture, when the HO2S detects a rich exhaust condition.
Certain vehicle models utilize an oxygen sensor behind the catalytic converter in order to monitor catalyst efficiency.
This diagnostic trouble code (DTC) determines if the HO2S is functioning properly. It checks for an adequate number of HO2S voltage transitions above and below the bias range of 300-600 mV. This DTC sets when the vehicle control module (VCM) fails to detect a minimum number of voltage transitions above and below the bias range during the test period. Possible causes of this DTC are:
• | An open or a short to voltage on either the HO2S signal or HO2S low circuits |
• | A malfunctioning HO2S |
• | A problem in the HO2S heater or its circuit |
• | A faulty HO2S ground |
This DTC is designed to detect an HO2S voltage that remains at a high, or rich, voltage for more than 100 seconds during a 120 second test period. This DTC is set under the following conditions:
• | There is an HO2S circuit fault that results in a false rich exhaust condition. |
• | The HO2S is correctly detecting the rich air/fuel ratio resulting from either a vacuum leak or a fuel control system problem. |
• | No active throttle position (TP) sensor DTCs |
• | No active evaporative emission (EVAP) system DTCs |
• | No active intake air temperature (IAT) sensor DTCs |
• | No active manifold absolute pressure (MAP) sensor DTCs |
• | No active engine coolant temperature (ECT) sensor DTCs |
• | No active mass air flow (MAF) sensor DTCs |
• | No active misfire DTCs |
• | No intrusive test in progress |
• | No device controls active |
• | The system voltage is between 11.7-18 volts. |
• | The system is in Closed Loop. |
• | The air/fuel ratio is between 14.5-14.8. |
• | The throttle position is between 1-50 percent. |
• | The above conditions are met for 5 seconds. |
• | The system is in Closed Loop. |
• | DFCO mode active |
• | The elapsed time since the test enabled is more than 2 seconds. |
The oxygen (O2) sensor voltage is more than 994 mV for more than 110 seconds.
The O2 sensor voltage is more than 469 mV for more than 40 seconds.
• | The control module illuminates the malfunction indicator lamp (MIL) if a failure is detected during 2 consecutive key cycles. |
• | The control module sets the DTC and records the operating conditions at the time the diagnostic failed. The failure information is stored in the scan tool Freeze Frame/Failure Records. |
• | The control module turns OFF the MIL after 3 consecutive drive trips when the test has run and passed. |
• | A history DTC will clear if no fault conditions have been detected for 40 warm-up cycles. A warm-up cycle occurs when the coolant temperature has risen 22°C (40°F) from the startup coolant temperature and the engine coolant reaches a temperature that is more than 70°C (158°F) during the same ignition cycle. |
• | Use a scan tool in order to clear the DTCs. |
Important: Never solder the HO2S wires. For proper wire and connection repair, refer to Wiring Repairs or Connector Repairs in Wiring Systems.
Check the following items:
• | The fuel pressure -- If the pressure is too high, the system will run rich. The VCM can compensate for some increase, however, if the pressure gets too high, this DTC may set. Refer to Fuel System Diagnosis . |
• | A rich injector. Perform an Injector Balance Test. Refer to Fuel Injector Balance Test with Tech 2 . |
• | A leaking injector -- Refer to Fuel System Diagnosis . |
• | Fuel contaminated oil |
• | EVAP canister purge -- Check for a fuel saturation. If full of fuel, check the canister control and hoses. Refer to Fuel System Cleaning . |
• | Leaking fuel pressure regulator diaphragm by checking the vacuum line to the regulator for fuel |
• | The TP sensor -- An intermittent TP sensor output causes the system to run rich due to a false indication of the throttle moving. |
• | False rich indication due to silicon contamination of the heated oxygen sensor -- This DTC, accompanied by a lean driveability condition and a powdery, white deposit on the sensor, may indicate a false rich condition. |
An intermittent may be caused by any of the following conditions:
• | A poor connection |
• | Rubbed through wire insulation |
• | A broken wire inside the insulation |
Thoroughly inspect any circuitry that is suspected of causing the intermittent complaint. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
If a repair is necessary, refer to Wiring Repairs or Connector Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
Monitor the HO2S voltage of the opposite bank sensor. If the voltage activity of the opposite bank sensor is similar to the voltage activity of the suspect sensor, check for rich conditions that would affect both cylinder banks. An opposite bank sensor with normal HO2S voltage activity indicates the suspect HO2S is defective, or a rich condition exists only on the suspect HO2S cylinder bank.
An HO2S contaminated by silicon will have a white, powdery deposit on the portion of the HO2S that is exposed to the exhaust stream. The usual cause of silica contamination is the use of unapproved silicon room temperature vulcanizing (RTV) engine gasket material or the use of silicon based sprays or fluids within the engine. If the cause of this contamination is not corrected, the replacement HO2S will also get contaminated.
Step | Action | Value(s) | Yes | No | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||||||||||||||||||
2 |
Is the HO2S voltage fixed more than the value specified? | 994 mV | ||||||||||||||||||
3 | This DTC is intermittent. Are any additional DTCs stored? | -- | Go to the applicable DTC table | Go to Diagnostic Aids | ||||||||||||||||
4 |
Is the HO2S voltage within the value range specified? | 351-551 mV | ||||||||||||||||||
Did you find a problem? | -- | |||||||||||||||||||
6 |
Is the voltage more than the specified value? | 20 mV | ||||||||||||||||||
7 | Repair the short to voltage in the HO2S HIGH signal circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |||||||||||||||||
Important: Before replacing a contaminated HO2S, determine and repair the cause of the contamination. Replace the HO2S. Refer to Heated Oxygen Sensor Replacement . Is the action complete? | -- | -- | ||||||||||||||||||
9 |
Important: The replacement VCM must be programmed. Replace the VCM. Refer to VCM Replacement/Programming . Is the action complete? | -- | -- | |||||||||||||||||
10 |
Important: If a rich engine condition was repaired, inspect the engine oil for fuel contamination and replace engine oil as necessary. Did this DTC run and pass? | -- | ||||||||||||||||||
11 | Does the scan tool display any additional undiagnosed DTCs? | -- | Go to the applicable DTC table | System OK |