The number(s) below refer to the step number(s) on the diagnostic table.
Lack of communication may be due to a partial malfunction of the class 2 serial data circuit or due to a total malfunction of the class 2 serial data circuit. The specified procedure will determine the particular condition.
There may be DTCs stored in other class 2 modules related to the instrument cluster.
The presence of DTCs which begin with U indicate some other module is not communicating. The specified procedure will compile all the available information before tests are performed.
Step | Action | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Install a scan tool. Does the scan tool power up? | Go to Step 2 | Go to Scan Tool Does Not Power Up in Data Link Communications | ||||||||||||||
Does the scan tool communicate with the control modules listed above? | Go to Step 3 | Go to Scan Tool Does Not Communicate with Class 2 Device in Data Link Communications | |||||||||||||||
Select the display DTCs function on the scan tool for the following control modules:
Does the scan tool display any DTCs for the control modules listed above? | Go to Step 4 | ||||||||||||||||
Does the scan tool display any DTCs which begin with a U? | Go to Scan Tool Does Not Communicate with Class 2 Device in Data Link Communications | Go to Step 5 | |||||||||||||||
5 | Does the scan tool display DTC B1397, B1398, or B1480? | Go to Diagnostic Trouble Code (DTC) List/Type in Body Control System |