Important: The following procedure should be utilized in the event that the sensor mounting holes or fasteners are damaged to the extent that the sensor may no longer be properly mounted.
7.1. | Remove and discard the improperly installed fastener. |
7.2. | Chisel off the damaged weld nut. |
7.3. | Condition the front end lower tie surface where the new weld nut is to be installed. |
7.4. | Install the new weld nut (GM P/N 11514034) or equivalent into position. |
7.5. | Migweld the new weld nut to the front end lower tie surface in the correct location. |
7.6. | Use the new fastener (GM P/N 11515926) or equivalent. |
Caution: Be careful when you handle a sensor. Do not strike or jolt a sensor.
Before applying power to a sensor:
• Remove any dirt, grease, etc. from the mounting surface. • Position the sensor horizontally on the mounting surface. • Point the arrow on the sensor toward the front of the vehicle. • Tighten all of the sensor fasteners and sensor bracket fasteners
to the specified torque value.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten fasteners to 10 N·m (89 lb in).