Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the exhaust manifold nuts to 50 N·m (39 lb ft).
• | Hose clip |
• | Transmission crossmember |
Notice: Refer to Fastener Notice in the Preface section.
1.1. | Apply anti-seize compound GM P/N 12377953 or equivalent to the threads of the old oxygen sensors. |
1.2. | Install the oxygen sensors. |
Tighten
Tighten the oxygen sensors to 42 N·m (31 lb ft).
Tighten
Tighten the nuts to 50 N·m (39 lb ft).
Tighten
Tighten the nuts to 40 N·m (30 lb ft).
• | Hose clip |
• | Transmission crossmember |
Tighten
Tighten the bolts to 95 N·m (70 lb ft).
Tighten
Tighten the nuts to 40 N·m (30 lb ft).
Tighten
Tighten the bolts to 20 N·m (15 lb ft).
Tighten
Tighten the bolts to 20 N·m (15 lb ft).