Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Schematic Reference: Instrument Cluster: Analog Schematics | ||||||||
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Does the Displayed Trans Oil Temp parameter match the transmission fluid temperature gauge display? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||
3 |
Does the scan tool indicate both parameters are approximately the same? | -- | Go to Step 4 | Go to Step 5 | ||||
4 | With the scan tool observe the Monitored Trans Oil Temp parameter in the IPC data list. Does the scan tool indicate the parameter is within the specified range? | -40°C to 215°C (-40°F to 419°F) | Go to Step 5 | Go to
| ||||
5 | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | -- | Go to Step 6 | -- | ||||
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |