Step | Action | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views | |||||||||||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |||||||||
2 | Verify that the roof beacon lamp is inoperative. Does the roof beacon lamp operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||
3 |
Does the test lamp illuminate? | Go to Step 8 | Go to Step 4 | ||||||||
4 | Test the ground circuit of the roof beacon lamp for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 5 | ||||||||
5 |
Does the roof beacon lamp illuminate? | Go to Step 9 | Go to Step 6 | ||||||||
6 | Test the following circuits for a high resistance, open or a short to ground:
Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 7 | ||||||||
7 | Test the ground circuit of the roof beacon relay for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 10 | ||||||||
8 | Replace the bulb or lamp assembly. Refer to upfitter instructions. Did you complete the replacement? | Go to Step 11 | -- | ||||||||
9 | Replace the roof beacon switch. Did you complete the replacement? | Go to Step 11 | -- | ||||||||
10 | Replace the roof beacon relay. Refer to Relay Replacement in Wiring Systems. Did you complete the replacement? | Go to Step 11 | -- | ||||||||
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |