Cleaning Procedure
- Clean the camshaft cover in solvent.
Caution: Wear safety glasses in order to avoid eye damage.
- Dry the
camshaft cover with compressed air.
Inspection Procedure
- Inspect the camshaft cover for the following:
• | Dent or damage to the exterior of the camshaft cover |
• | A dented or damaged cover may: |
- | Effect crankcase ventilation |
- | Interfere with the camshafts |
- | Interfere with the ignition module sealing |
- | Allow water or condensation to enter the engine |
• | Damaged camshaft cover bolts |
• | Damage or cracking to the camshaft cover bolt grommets |
• | Restrictions to the ventilation system passages |
• | Damaged, loose or missing baffle |
• | Damaged, loose or missing baffle fasteners |
• | Damage to the oil fill hole in the left camshaft cover |
• | Damage or cracking to the PCV grommet in the left camshaft cover |
• | Damage to the ventilation hose nipple in the right
camshaft cover |
• | Damaged threaded holes. |
• | Damage or warped seal grooves. |
- Repair or replace the camshaft cover as necessary.