Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the Defogger System Check been performed? | -- | Go to Step 2 | Go to Defogger System Check |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair open in CKT 150 (BLK) between HVAC control module connector C1and G200. Refer to Wiring Repairs in wiring. Is the repair complete? | -- | Go to Defogger System Check | -- |
4 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 | Locate and repair open in CKT 150 (BLK) between HVAC control module connector C3 and G200. Refer to Wiring Repairs in wiring. Is the repair complete? | -- | Go to Defogger System Check | -- |
6 | Connect a J 35616-200 test lamp from cavity B of HVAC control module connector C1 and ground. Does the test lamp light? | Go to Step 8 | Go to Step 7 | |
7 | Locate and repair open in CKT 141 (BRN) between the IP fuse block and the HVAC control module connector C1. Refer to Wiring Repairs in wiring. Is the repair complete? | -- | Go to Defogger System Check | -- |
8 | Replace the HVAC control module. Refer to Control Assembly Replacement in instrument cluster. Is the repair complete? | -- | Go to Defogger System Check | -- |