The number(s) below refer to the step number(s) on the diagnostic table.
This step will determine if one or more blower speeds are inoperative.
This step determines if there is battery positive voltage at the blower motor resistor assembly.
This step tests for voltage in each blower motor control circuit.
This step tests for an open in the blower motor resistor assembly.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor operates in at least one, but not all, speed positions. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
Does the blower motor operate in each speed position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 6 | |
Important: Ensure the blower motor switch is in the correct speed position for the blower motor control circuit being tested.
Does the test lamp illuminate in each speed position? | Go to Step 5 | Go to Step 7 | |
Does the test lamp illuminate in each speed position? | Go to Step 8 | Go to Step 9 | |
6 | Repair the battery positive voltage circuit to the blower motor resistor assembly for an open or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | -- |
7 | Test the appropriate blower motor control circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
8 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 11 | -- |
9 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 11 | -- |
10 | Replace the HVAC control module. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |