Important:
• Remove any debris from the transmission control module (TCM) connector
surfaces before servicing the TCM. Inspect the TCM module connector gaskets when
diagnosing or replacing the TCM. Ensure that the gaskets are installed correctly.
The gaskets prevent contaminant intrusion into the TCM. • The ignition must be OFF when disconnecting or reconnecting power to
the TCM.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the bolts to 9 N·m (80 lb in).