Removal Procedure
- Loosen the outlet duct clamps at the turbocharger
and the mass air flow (MAF)/intake air temperature (IAT) sensor.
- Remove the air cleaner outlet duct.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
Important: The air cleaner outlet duct must be fully
seated against the positive stop feature on the turbocharger inlet.
- Install the air cleaner outlet duct.
- Tighten the outlet duct clamps at the turbocharger and the MAF/IAT sensor.
Tighten
Tighten the clamps to 4 N·m (35 lb in).