Backup Lamp Replacement Ambulance Body
Removal Procedure
- Remove the backup lamp bulb. Refer to
Backup Lamp Bulb Replacement
.
- Remove the backup lamp nuts (2).
- Disconnect the electrical connector (1) from the backup lamp.
- Remove the lamp assembly.
Installation Procedure
- Install the lamp assembly.
- Connect the electrical connector (1) to the backup lamp.
Notice: Refer to Fastener Notice in the Preface section.
- Install the nuts (2) for the backup lamp.
Tighten
Tighten screws to 0.8N·m (7 lb in).
- Install the backup lamp bulb. Refer to
Backup Lamp Bulb Replacement
.