Slave Receptacle Replacement LSSV

Removal Procedure

    Caution: Refer to Battery Disconnect Caution in the Preface section.


    Object Number: 1706968  Size: SH
  1. Disconnect the battery cables. Refer to Battery Cable Disconnect and Connection .
  2. Unscrew the slave receptacle cover (1).
  3. Remove the fasteners (2) securing the slave receptacle to the radiator grille guard bracket.
  4. Remove the slave receptacle (3).

  5. Object Number: 1706663  Size: SH
  6. Disconnect the negative cable connections (2).
  7. Remove the rubber cover from the rear of the positive cable connection.
  8. Disconnect the positive cable connection (3).
  9. Remove the slave receptacle and the gasket from the bracket.

Installation Procedure


    Object Number: 1706663  Size: SH

    Important: The gasket must mount to the square back of the slave start connector assembly.

  1. Position the slave receptacle with the gasket onto the bracket.
  2. Install the positive cable onto the connection (3).
  3. Notice: Refer to Fastener Notice in the Preface section.

  4. Install the negative cable onto the connection (2).
  5. Tighten
    Tighten the connections to 20 N·m (15 lb ft).


    Object Number: 1706968  Size: SH
  6. Install the rubber cover onto the rear of the positive cable connection.
  7. Position the slave receptacle cover onto the rear of the bracket.
  8. Install the fasteners (2) onto the slave receptacle (3) and the slave receptacle cover (1).
  9. Tighten
    Tighten the bolts to 8 N·m (71 lb in).

  10. Install the slave receptacle cover (1).
  11. Connect the battery cables. Refer to Battery Cable Disconnect and Connection .

Slave Receptacle Replacement Ambulance/Maintenance Body

Removal Procedure

    Caution: Refer to Battery Disconnect Caution in the Preface section.


    Object Number: 1706662  Size: SH
  1. Disconnect the battery cables. Refer to Battery Cable Disconnect and Connection .
  2. Unscrew the slave receptacle cover (2).
  3. Remove the fasteners (3) securing the slave receptacle to the slave receptacle and connect the rear connector cover (1).
  4. Remove the slave receptacle cover (2).

  5. Object Number: 1706663  Size: SH
  6. Disconnect the negative cable connections (2).
  7. Remove the rubber cover from the rear of the positive cable connection.
  8. Disconnect the positive cable connection (3).
  9. Remove the slave receptacle and the gasket from the bracket.

Installation Procedure


    Object Number: 1706663  Size: SH

    Important: The gasket must mount to the square back of the slave start connector assembly.

  1. Position the slave receptacle with the gasket onto the bracket.
  2. Install the positive cable onto the connection (3).
  3. Notice: Refer to Fastener Notice in the Preface section.

  4. Install the negative cable onto the connection (2).
  5. Tighten
    Tighten the connections to 20 N·m (15 lb ft).


    Object Number: 1706662  Size: SH
  6. Install the rubber cover onto the rear of the positive cable connection.
  7. Position the slave receptacle cover (1) onto the rear of the bracket.
  8. Install the fasteners (3) onto the slave receptacle and through the slave receptacle rear connector cover.
  9. Tighten
    Tighten the bolts to 8 N·m (71 lb in).

  10. Install the slave receptacle cover (2).
  11. Connect the battery cables. Refer to Battery Cable Disconnect and Connection .