When you start the vehicle, the oil pump generates fluid flow from the transmission sump through the filter and into the pump. Filtered transmission fluid is directed to the pressure regulator valve.
Pressure Regulator Valve: The pressure regulator valve regulates line pressure according to various driving conditions. The converter feed pressure is directed to the torque converter hydraulic system. Regulated line pressure is directed
to the torque converter clutch regulated apply valve, the actuator feed limit valve, and the manual valve.
Torque Converter Clutch Regulated Apply Valve (TCCRAV): Line pressure is supplied to the TCCRAV to be utilized in other gear ranges.
Actuator Feed Limit Valve: This valve regulates the actuator feed pressure to the 1-2, 2-3, 3-4 shift valves, to the pressure control solenoid valve, and to the 1-2 and 2-3 shift solenoid valves.
Manual Valve: The line pressure from the pressure regulator valve is supplied to the manual valve in order to be utilized in other gear ranges. In Park range, line pressure is directed as PRND43, PRND4, and PRN fluid pressure.
Automatic Transmission Fluid Pressure (TFP) Manual Valve Position Switch Assembly: PRND4 and PRND43 fluid pressures from the manual valve are directed to their respective switches on the TFP manual valve position switch. This sends
a signal to the PCM that the transmission is in Park range.
1-2 Shift Solenoid (1-2 SS) Valve: When the 1-2 SS valve is energized, 1-2 signal fluid pressure forces the 1-2 shift valve to the extreme left against a spring force.
2-3 Shift Solenoid (2-3 SS) Valve: When the 2-3 SS valve is de-energized, 2-3 signal fluid exhausts through the solenoid. A spring force holds the 2-3 shift valve to the extreme right.
1-2 Shift Valve: 1-2 signal fluid pressure holds the 1-2 shift valve to the left against a spring force.
2-3 Shift Valve: Spring force holds the 2-3 shift valve to the extreme right. This action blocks the PRND4 fluid pressure at the 2-3 Shift Valve.
3-4 Shift Valve: Spring force and PRN fluid pressure hold the 3-4 shift valve to the extreme right.
Manual 2-1 Band Servo: PRND43 fluid pressure from the manual valve is directed to the manual 2-1 band servo. This pressure assists the spring force in holding the manual 2-1 band servo off.
Park or Neutral - Engine Running
When you start the vehicle, the oil pump generates
fluid flow from the transmission sump through the filter and into the pump.
Filtered transmission fluid is directed to the pressure regulator valve.
Pressure Regulator Valve: The pressure regulator valve regulates line pressure according
to various driving conditions. The converter feed pressure is directed to
the torque converter hydraulic system. Regulated line pressure is directed
to the torque converter clutch regulated apply valve, the actuator feed limit
valve, and the manual valve.
Torque Converter Clutch Regulated Apply Valve (TCCRAV): Line pressure is supplied to the TCCRAV to be utilized in other
gear ranges.
Actuator Feed Limit Valve: This valve regulates the actuator feed pressure to the 1-2, 2-3,
3-4 shift valves, to the pressure control solenoid valve, and to the 1-2 and
2-3 shift solenoid valves.
Manual Valve: The line pressure from the pressure regulator valve is supplied
to the manual valve in order to be utilized in other gear ranges. In Park
range, line pressure is directed as PRND43, PRND4, and PRN fluid pressure.
Automatic Transmission Fluid Pressure (TFP) Manual Valve Position Switch
Assembly: PRND4 and PRND43 fluid pressures from the manual valve are directed
to their respective switches on the TFP manual valve position switch. This
sends a signal to the PCM that the transmission is in Park range.
1-2 Shift Solenoid (1-2 SS) Valve: When the 1-2 SS valve is energized, 1-2 signal fluid
pressure forces the 1-2 shift valve to the extreme left against a spring
force.
2-3 Shift Solenoid (2-3 SS) Valve: When the 2-3 SS valve is de-energized, 2-3 signal
fluid exhausts through the solenoid. A spring force holds the 2-3 shift
valve to the extreme right.
1-2 Shift Valve: 1-2 signal fluid pressure holds the 1-2 shift valve
to the left against a spring force.
2-3 Shift Valve: Spring force holds the 2-3 shift valve to the extreme right.
This action blocks the PRND4 fluid pressure at the 2-3 Shift Valve.
3-4 Shift Valve: Spring force and PRN fluid pressure hold the 3-4 shift valve to
the extreme right.
Manual 2-1 Band Servo: PRND43 fluid pressure from the manual valve is directed to the
manual 2-1 band servo. This pressure assists the spring force in holding
the manual 2-1 band servo off.
Park or Neutral - Engine Running