Removal Procedure
- Remove the generator from the vehicle. Refer to
Generator Replacement
.
- Remove the tensioner from the generator bracket. Refer to
Drive Belt Tensioner Replacement
.
- Remove the idler pulley from the generator bracket. Refer to
Drive Belt Idler Pulley Replacement
.
- Remove the retaining bolts (3) and nut (2) from
the generator bracket (1).
- Remove the generator bracket (1) from the engine.
Installation Procedure
- Install the generator bracket to the engine.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator
bracket retaining bolts (3) and nut (2) to the generator bracket (1).
Tighten
• | Tighten the generator mounting bracket bolts to 66 N·m
(49 lb ft). |
• | Tighten the generator mounting bracket nut to 66 N·m
(49 lb ft). |
- Install the idler pulley to the generator bracket. Refer to
Drive Belt Idler Pulley Replacement
.
- Install the tensioner to the generator bracket. Refer to
Drive Belt Tensioner Replacement
.
- Install the generator to the vehicle. Refer to
Generator Replacement
.