Removal Procedure
- Disconnect the negative battery
cable.
- Disconnect the electrical connector from the blower motor relay.
- Remove the retaining screw.
- Remove the blower motor relay from the evaporator housing.
Installation Procedure
- Install the blower motor relay to the evaporator housing.
- Install the blower motor relay retaining
screw.
Tighten
Tighten the screw to 1.9 N·m (18 lb in).
- Connect the electrical connector to the blower motor relay.
- Connect the negative battery cable.
Tighten
Tighten the negative battery cable bolt to 17 N·m (13 lb ft).