Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Twilight Sentinel System Check? | -- | Go to Step 2 | |
2 |
Does the headlamp system function properly? | -- | Go to Step 3 | Go to Step 11 |
3 |
Does test lamp light? | -- | Go to Step 4 | Go to Step 12 |
4 | Connect a J 35616-200 test lamp between connector C1 cavity E and ground. Does test lamp light? | -- | Go to Step 5 | Go to Step 13 |
5 | Connect a J 35616-200 test lamp between connector C1 cavity F and B+. Does test lamp light? | -- | Go to Step 6 | Go to Step 14 |
6 | Connect a J 35616-200 test lamp between connector C1 cavity C and B+. Does test lamp light? | -- | Go to Step 15 | Go to Step 7 |
7 |
Does test lamp light? | -- | Go to Step 8 | Go to Step 16 |
8 |
Is there continuity? | -- | Go to Step 9 | Go to Step 16 |
9 | Replace headlamp control module. Is the repair complete? | -- | -- | |
10 |
Is the repair complete? | -- | Go to Step 3 | |
11 | Locate and repair open in CKT 39 (PNK) between headlamp control module and IP fuse block. Is the repair complete? | -- | Go to Step 4 | |
12 | Locate and repair open in CKT 240 (ORN) between headlamp control module and IP fuse block. Is the repair complete? | -- | Go to Step 5 | |
13 | Locate and repair open in CKT 150 (BLK) between headlamp control module and ground G202. Is the repair complete? | -- | Go to Step 6 | |
14 |
Is the repair complete? | -- | Go to Step 7 | |
15 | Locate and repair open in CKT 2040 (ORN) between headlamp control module and IP fuse block. Is the repair complete? | -- | Go to Step 8 | |
16 |
Is there continuity? | -- | Go to Step 17 | Go to Step 18 |
17 | Replace inside automatic day-night mirror. Is the repair complete? | -- | -- | |
18 | Locate and repair open in CKT 1784 (YEL/BLK) between automatic day-night mirror and headlamp control module. Is the repair complete? | -- | Go to Step 8 |