The number(s) below refer to the step number(s) on the diagnostic table.
The HVAC control module is inoperative when the module does not respond to any operator control requests.
When the blower motor is in the OFF position, a voltage is applied to the OFF blower motor control circuit. The A/C system will not operate if a voltage is applied to the OFF blower motor control circuit.
Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Compressor Control Schematics DEFINITION: A/C compressor clutch will not engage when an A/C request has been made and no Powertrain DTC has been set. Important:
| ||||||||||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms | ||||||||
2 |
Important: : For A/C compressor operation, outside air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||
3 |
Are both the low and high side pressures within 103 kPa (15 psi) of the ambient temperature? | -- | Go to Step 4 | Go to Leak Testing in Heating, Ventilation and Air Conditioning | ||||||||
Is the HVAC control module inoperative? | -- | Go to Step 22 | Go to Step 5 | |||||||||
5 |
Does the scan tool indicate that the A/C request parameter is ON? | -- | Go to Step 8 | Go to Step 6 | ||||||||
6 | Does the A/C request indicator illuminate? | -- | Go to Step 7 | Go to Step 24 | ||||||||
7 |
IMPORTANT:: Ensure that the blower motor switch is not in the OFF position during this step.
Does the scan tool indicate that the A/C request parameter is ON? | -- | Go to Step 34 | Go to Step 29 | ||||||||
8 | Does the scan tool indicate the A/C low pressure switch parameter is closed? | -- | Go to Step 10 | Go to Step 9 | ||||||||
9 |
Does the scan tool indicate the A/C low pressure switch parameter is closed? | -- | Go to Step 30 | Go to Step 25 | ||||||||
10 | With a scan tool, command the A/C compressor clutch relay ON and OFF. Does the A/C compressor clutch relay turn ON and OFF with each command? | -- | Go to Step 19 | Go to Step 11 | ||||||||
11 |
Does the test lamp illuminate? | -- | Go to Step 12 | Go to Step 18 | ||||||||
12 |
Does the test lamp turn ON and OFF with each command? | -- | Go to Step 16 | Go to Step 13 | ||||||||
13 | Does the test lamp remain illuminated with each command? | -- | Go to Step 15 | Go to Step 14 | ||||||||
14 | Test the control circuit of the A/C compressor clutch relay for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 38 | ||||||||
15 | Test the control circuit of the A/C compressor clutch relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 38 | ||||||||
16 | Inspect for poor connections at the A/C compressor clutch relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 17 | ||||||||
17 | Replace the A/C compressor clutch relay. Did you complete the replacement? | -- | Go to Step 40 | -- | ||||||||
18 | Repair the coil side voltage supply circuit of the A/C compressor clutch relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 40 | -- | ||||||||
19 |
Does the test lamp illuminate? | -- | Go to Step 20 | Go to Step 21 | ||||||||
20 |
Does the A/C compressor clutch engage? | -- | Go to Step 16 | Go to Step 27 | ||||||||
21 | Repair the switch side voltage supply circuit of the A/C compressor clutch relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 40 | -- | ||||||||
22 | Test the ignition 3 voltage circuit of the HVAC control module for a short to ground, a high resistance, or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 23 | ||||||||
23 | Test the ground circuit of the HVAC control module for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 32 | ||||||||
IMPORTANT:: Ensure that the blower motor switch is not in the OFF position during this step. Test the OFF blower motor control circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 32 | |||||||||
25 | Test the A/C low pressure switch signal circuit for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 26 | ||||||||
26 | Test the ground circuit of the A/C low pressure switch for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 38 | ||||||||
27 | Test the A/C compressor clutch supply voltage circuit at the A/C compressor clutch for a short to ground, a high resistance, or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 28 | ||||||||
28 | Test the ground circuit of the A/C compressor clutch for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 31 | ||||||||
29 |
Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 38 | ||||||||
30 | Inspect for poor connections at the harness connector of the A/C low pressure switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 33 | ||||||||
31 | Inspect for poor connections at the harness connector of the A/C compressor clutch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 36 | ||||||||
32 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 37 | ||||||||
33 | Replace the A/C low pressure switch. Did you complete the replacement? | -- | Go to Step 40 | -- | ||||||||
34 | Inspect for poor connections at the harness connector of the A/C high pressure switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 35 | ||||||||
35 | Replace the A/C high pressure switch. Did you complete the replacement? | -- | Go to Step 40 | -- | ||||||||
36 | Replace the A/C compressor clutch coil. Refer to Air Conditioning Clutch Coil Removal and Air Conditioning Clutch Coil Installation in Heating, Ventilation, and Air Conditioning. Did you complete the replacement? | -- | Go to Step 40 | -- | ||||||||
37 | Replace the HVAC control module. Refer to Control Assembly Replacement . Did you complete the replacement? | -- | Go to Step 40 | -- | ||||||||
38 | Inspect for poor connections at the harness connector of the powertrain control module (PCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 40 | Go to Step 39 | ||||||||
39 |
Important:: Perform the reprogramming procedure for the PCM. Replace the Vehicle Control Module (VCM) or Powertrain Control Module (PCM). Refer to VCM Replacement/Programming in Engine Controls - 4.3L or Powertrain Control Module Replacement in Engine Controls - 4.8L, 5.3L, and 6.0L. Did you complete the replacement? | -- | Go to Step 40 | -- | ||||||||
40 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |