The retained accessory power (RAP) function allows certain systems such as the radio, the power windows and the sunroof (if equipped) to operate 20 minutes after the ignition switch is turned OFF. The body control module (BCM) monitors the ignition switch position, the mini wedge (door jamb) switches and the voltage on the RAP relay control circuit. The BCM will command the RAP relay ON by grounding the RAP relay control circuit.
• | The system voltage must be between 9.0 and 16.0 volts. |
• | The doors must remain closed. |
• | The ignition switch must be cycled ON to OFF. |
• | The radio or power windows must be operated to verify operation. |
• | When the BCM detects battery voltage (short to battery) on the RAP relay control circuit with the ignition switch in the RUN position. |
• | The above conditions must be met for 0.5 seconds. |
The radio, the power windows and the sunroof (if equipped) will not operate after the ignition switch is turned OFF and all the doors are closed.
• | A history DTC will clear after 100 consecutive ignition cycles without a fault present. |
• | History and current DTC(s) may be cleared by using a scan tool. |
• | Perform a visual inspection for loose or poor connections at all related components. |
• | Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
The number(s) below refer to the step number(s) on the diagnostic table.
Listen for an audible click when the Retained Accessory Power (RAP) relay operates. Command both the ON and OFF states. Repeat the commands as necessary.
Tests for voltage at the coil side of the RAP relay. The RAP fuse supplies power to the coil side of the RAP relay.
Verifies that the Body Control Module (BCM) is providing ground to the RAP relay.
Tests if ground is constantly being applied to the RAP Relay.
After replacement of the BCM you must calibrate the new module for proper operation.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Retained Accessory Power (RAP) Diagnostic System Check? | -- | Go to Step 2 | |
Does the RAP relay turn ON and OFF with each command? | -- | Go to Diagnostic Aids | Go to Step 3 | |
Does the test lamp illuminate? | -- | Go to Step 4 | Go to Step 10 | |
Does the test lamp turn ON and OFF with each command? | -- | Go to Step 8 | Go to Step 5 | |
Does the test lamp remain illuminated with each command? | -- | Go to Step 7 | Go to Step 6 | |
6 | Test the control circuit of the RAP relay for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 9 |
7 | Test the control circuit of the RAP relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at the RAP relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the Body Control Module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 12 |
10 | Repair the coil side feed circuit of the RAP relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 13 | -- |
11 | Replace the RAP relay. Did you complete the replacement? | -- | Go to Step 13 | -- |
Did you complete the replacement? | -- | Go to Step 13 | -- | |
13 |
Does the DTC reset? | -- | Go to Step 2 | System OK |