Important: If the suspected cause of an inoperative sunroof is a power interruption to the sunroof module, the sunroof must be re-initialized. Refer to Sunroof Motor Synchronization .
Important: The following must be completed before using the symptom tables.
• | There are no DTCs set. |
• | The control module(s) can communicate via the serial data link. |
• | Inspect for aftermarket devices which could affect the operation of the Power Sunroof system. Refer to Checking Aftermarket Accessories in Wiring Systems. |
• | Inspect the easily accessible or visible system components for obvious damage or conditions which could cause the symptom. |
Faulty electrical connections or wiring may be the cause of intermittent conditions. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
Refer to a symptom diagnostic procedure from the following list in order to diagnose the symptom:
• | Retained Accessory Power (RAP) On After Timeout in Retained Accessory Power, if the power sunroof should operate longer than 20 minutes after the ignition has been turned OFF |