Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the HVAC Blower Controls System Check performed? | -- | Go to Step 2 | |
2 |
Is there continuity? | -- | Go to Step 4 | Go to Step 3 |
3 | Replace the blower motor relay high. Refer to Blower Motor Relay Replacement . Is the repair complete? | -- | -- | |
4 |
Is there continuity? | -- | Go to Step 5 | Go to Step 8 |
5 | Connect a J 39200 between the blower motor connector C1, cavity A and cavity C1 of the blower motor relay high. Is there continuity? | -- | Go to Step 6 | Go to Step 9 |
6 |
Does the motor spin freely? | -- | Go to Step 10 | Go to Step 7 |
7 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | -- | |
8 | Repair the open in CKT 150 (BLK) between the blower motor and ground G202. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
9 | Repair the open in CKT 65 (PPL) between the blower motor relay high and the blower motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
10 |
Is battery voltage present? | -- | Go to Step 12 | Go to Step 11 |
11 | Repair the open in CKT 141 (BRN) between the instrument panel (IP) fuse block and the HVAC control module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
12 | Replace the HVAC control module. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- |