Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Backup Lights System Check ? | -- | Go to Step 2 | Go to Backup Lamp System Check | ||||
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 | ||||
3 | Connect a J 39200 DMM from the switch connector, terminal F (automatic) or terminal A (manual) to ground. Is there continuity? | -- | Go to Step 5 | Go to Step 6 | ||||
4 | Repair the open in CKT 139 (PNK) between the instrument panel fuse block and the park/neutral position switch (automatic), backup lamp switch (manual). Is the repair complete? | -- | Go to Backup Lamp System Check | -- | ||||
5 |
Is the repair complete? | -- | Go to Backup Lamp System Check | -- | ||||
6 |
Did you find and correct a condition? | -- | Go to Backup Lamp System Check | Go to Step 7 | ||||
7 | Repair the open in CKT 150 (BLK) between the backup lamps and ground G401. Is the repair complete? | -- | Go to Backup Lamp System Check | -- |