Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Wiper/Washer Schematics DEFINITION: The low washer fluid indicator always indicates low washer fluid or does not turn on with low washer fluid. | |||
1 | Did you review the Wiper/Washer System Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the low washer fluid indicator illuminate for 60 seconds after the ignition is turned ON? | Go to Step 6 | Go to Step 4 |
4 |
Does the low washer fluid indicator illuminate for 60 seconds after the ignition is turned ON? | Go to Step 5 | Go to Step 7 |
5 |
Does the low washer fluid indicator illuminate for 60 seconds after the ignition is turned ON? | Go to Step 9 | Go to Step 8 |
6 | Test the washer fluid level switch signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
7 | Test the washer fluid level switch signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
8 | Repair the washer fluid level switch ground circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 13 | -- |
9 | Inspect for poor connections at the washer fluid level switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 10 |
10 | Replace the washer fluid level switch. Refer to Washer Pump/Reservoir Replacement . Is the repair complete? | Go to Step 13 | -- |
11 | Inspect for poor connections at the instrument panel cluster. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
12 | Replace the instrument panel cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages, and Console. Is the repair complete? | Go to Step 13 | -- |
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |