Tools Required
J 38185 Hose Clamp Pliers
Removal Procedure
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Lower the vehicle.
- Disconnect the low coolant sensor electrical
connector.
- Remove the low coolant sensor electrical harness from the retainer.
- Use theJ 38185
in order to
reposition the surge tank outlet hose clamp (2) from the surge tank .
- Remove the surge tank outlet hose from the surge tank .
- Use theJ 38185
in order
to reposition the engine vent hose clamp (4) from the surge tank .
- Remove the engine vent hose from the surge tank .
- Use theJ 38185
in order
to reposition the radiator vent hose clamp (3) from the surge tank .
- Remove the radiator vent hose from the surge tank .
- Remove the radiator surge tank mounting bolt.
- Remove the surge tank.
Installation Procedure
- Install the surge tank.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the surge tank mounting bolt.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
Install the radiator vent hose to the surge tank .
- Use theJ 38185
in order
to reposition the radiator vent hose clamp (3) to the surge tank.
- Install the engine vent hose to the surge tank .
- Use theJ 38185
in order
to reposition the engine vent hose clamp (4) to the surge tank.
- Install the surge tank outlet hose to the surge tank .
- Use theJ 38185
in order
to reposition the surge tank outlet hose clamp (2) to the surge tank.
- Install the low coolant sensor electrical
connector to the retainer.
- Connect the low coolant electrical connector.
- Fill the cooling system at the radiator surge tank. Refer to
Cooling System Draining and Filling
.