Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.
- Remove the nut retaining the positive battery cable lead to the underhood
electrical center, then reposition the cable lead away from the electrical center.
- Remove the electrical center cover.
- Remove all of the fuses and the relays.
- Reach under the front of the electrical
center and press up on the relief in order to release the retainer tab.
- While pressing up, slide the electrical center forward.
- Disconnect the electrical cable retainers
at the rear of the electrical center.
- Release the box retainer next to the electrical cables.
- Turn the electrical center upside down and
open the lower cover.
- Disconnect the instrument panel (I/P) wiring
harness individual connectors from the junction block.
- Loosen the bolts retaining the engine, I/P, and forward lamp wiring harness
connectors to the junction block.
- Disconnect the engine wiring harness connector
from the junction block.
- Disconnect the I/P wiring harness connector
from the junction block.
- Disconnect the forward lamp wiring harness
connector from the junction block.
- Remove the electrical center box.
Installation Procedure
- With the electrical center turned upside down, install the electrical
center box into the electrical center.
- Connect the forward lamp wiring harness
connector to the junction block.
- Connect the I/P wiring harness connector
to the junction block.
- Connect the engine wiring harness connector
to the junction block.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the bolts retaining the engine, I/P, and forward lamp wiring harness
connectors to the junction block.
Tighten
Tighten the electrical center junction block bolts
to 7 N·m (62 lb in).
- Connect the I/P wiring harness
individual connectors to the junction block.
- Connect the retainers for the electrical
cable at the rear of the electrical center.
- Install the box retainers by the electrical cables.
- Close the lower cover of the electrical
center.
- Turn the electrical center right side up.
- Attach the box retainer next to the electrical cables.
- Connect the electrical cable retainers at the rear of the electrical
center.
- Slide the electrical center to the rear
until the center snaps into the retainer tab.
- Install all of the fuses and the relays.
- Install the electrical center cover.
- Install the positive battery cable lead to the stud on underhood electrical
center, then install the positive battery cable lead retaining nut.
Tighten
Tighten the positive battery cable lead retaining
nut to 10 N·m (89 lb in).
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.