Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Does the blower motor operate in the desired speeds? | Go to Step 5 | Go to Blower Motor Malfunction |
5 |
Does the recirculation door move from the recirculation position to the outside air position? | Go to Step 6 | |
6 | Place the mode switch in the defrost position. Does the recirculation door move to the outside air position? | Go to Step 7 | Go to Step 8 |
7 | Place the mode switch in each mode position. Does the air flow from the proper air distribution outlets in each mode position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |
8 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
9 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |