Removal Procedure
- Disconnect the engine harness electrical connector
from the mass air flow (MAF)/intake air temperature (IAT) sensor.
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Release the air cleaner latches.
- Separate the upper and lower portions of the air cleaner assembly.
- Remove the air cleaner filter from the lower air cleaner housing.
- Inspect the air cleaner filter for dust, dirt, and water contamination.
Installation Procedure
- Install the air cleaner filter into the lower air
cleaner housing.
- Install the upper air cleaner cover to the lower air cleaner housing.
- Engage the air cleaner latches.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Connect the engine harness electrical connector to the MAF/IAT sensor.