• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each of the diagnostic category. |
Control Module Command | EVAP Canister Purge Solenoid Valve | EVAP Canister Vent Solenoid Valve |
---|---|---|
ON | Open | Closed |
OFF | Closed | Open |
This DTC tests for undesired intake manifold vacuum flow to the evaporative emission (EVAP) system. The engine control module (ECM) seals the EVAP system by commanding the EVAP canister purge solenoid valve OFF and the EVAP canister vent solenoid valve ON. The ECM monitors the fuel tank pressure (FTP) sensor to determine if a vacuum is being drawn on the EVAP system. If vacuum in the EVAP system is more than a predetermined value within a predetermined time, this DTC sets. The following table illustrates the relationship between the ON and OFF states, and the Open or Closed states of the EVAP canister purge and vent solenoid valves.
• | DTCs P0068, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0122, P0123, P0125, P0128, P0220, P0222, P0228, P0443, P0449, P0452, P0453, P0454, P0502, P0503, P0606, P0641, P0651, P0722, P0723, P2135 are not set. |
• | The ignition voltage is between 11-18 volts. |
• | The barometric pressure (BARO) is more than 70 kPa. |
• | The fuel level is between 10-90 percent. |
• | The start-up engine coolant temperature (ECT) is less than 35°C (95°F). |
• | The start-up intake air temperature (IAT) is between 4-30°C (39-86°F). |
• | The start-up ECT and IAT are within 8°C (14.4°F) of each other. |
• | DTC P0496 runs once per cold start within 17 minutes. |
• | The ECM detects vacuum during a non-purge condition. |
• | The fuel tank vacuum is greater than 10 inches H2O for 5 seconds within 60 seconds of cold start. |
DTC P0496 is a Type B DTC.
DTC P0496 is a Type B DTC.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If the Fuel Tank Pressure Sensor parameter is greater than the specified range, replace the EVAP canister purge solenoid valve. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Evaporative Emission Canister Purge Solenoid Valve Replacement