J 45059 Angle Meter
For equivalent regional tools, refer to Special Tools
Caution: Refer to Fastener Caution in the Preface section.
6.1. | Tighten the crankshaft bearing bolts in sequence to 20 N·m (15 lb ft). |
6.2. | Using the J 45059 meter , tighten the crankshaft bearing bolts in sequence to 77 degrees. |
Note: Do not forget the 2 rear outer bolts.