J 45059 Angle Meter
For equivalent regional tools, refer to Special Tools
Note: Do not use any sealing material.
Caution: Refer to Fastener Caution in the Preface section.
Note: Always use NEW cylinder head bolts.
3.1. | Tighten the bolts in sequence to 30 N·m (22 lb ft). |
3.2. | Tighten the bolts an additional 155 degrees in sequence using the J 45059 meter . |