Cooling Fan Inoperative 2.2L
Diagnostic Instructions
Circuit/System Description
The engine control module (ECM) grounds the low speed relay, which is relay 1, and the high speed relay, which is relay 2, control circuits through an internal solid state device called a driver. The primary function of the driver is to supply
the ground for the component being controlled. Each driver has a fault line that is monitored by the ECM. When the ECM is commanding a component ON, the voltage potential of the control circuit should be low, near 0 volt. When the ECM is commanding the
control circuit to a component OFF, the voltage potential of the circuit should be high, near battery voltage. If the ECM detects that the actual state of the control circuit does not match the expected state, a DTC will set.
Reference Information
Schematic Reference
Engine Cooling Schematics
Connector End View Reference
Description and Operation
Cooling Fan Description and Operation
Electrical Information Reference
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
- If DTCs P0480 or P0481 are set, then perform those diagnostics first.
- Ignition ON, command each relay ON and OFF with a scan tool. Observe to verify that the fan turns ON and OFF with each command.
Circuit/System Testing
Note: You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the affected Relay.
- Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. |
- Disconnect the harness connector at the cooling fan.
- Test for less than 1.0 ohm between the cooling fan ground circuit terminal 3 and ground.
⇒ | If not the specified range, test the ground circuit for an open/high resistance. |
- Connect the harness connector at the cooling fan.
- Connect a 30A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the cooling fan is activated.
⇒ | If the cooling fan does not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the cooling fan. |
- If all circuits test normal, test or replace the Relay.
Repair Instructions
Repair Verification
Ignition ON, command each relay ON and OFF with a scan tool. Observe to verify that each fan turns ON and OFF with each command.
Cooling Fan Inoperative 2.0
Diagnostic Instructions
Circuit/System Description
The engine control module (ECM) commands the fans ON in either high speed or low speed, depending on cooling requirements. In low speed, both fans are turned ON at a reduced speed. High speed has both fans turned ON at full speed.
In low speed operation, the ECM applies ground to the coil side of the fan low relay. This energizes the coil and applies voltage directly to the left cooling fan through the switch side of the fan low relay, which is fed by the fan 1 fuse. The right fan
is connected in series to the left fan through the de-energized series/parallel relay, which is the fan control relay so that both operate at low speed.
In high speed operation, the ECM applies a ground to the coil side of the fan low relay, the fan control relay , and the fan high relay. On the fan high relay, the energized coil closes the switch side of the relay and applies voltage directly to the right
cooling fan through the switch side of the relay, which is fed by the fan 2 fuse. At the same time, the ECM energizes fan control relay pulling the switch side over, providing a direct path to ground for the left cooling fan, which has voltage applied
through the energized fan low relay. In high speed mode, the fans are operated as a parallel circuit with full voltage applied to each.
Diagnostic Aids
The ECM has the capability of providing command to the fan relays even while a scan tool output control is being used. Always refer to the fan control command parameters on the scan tool to know which fans are being commanded ON by the ECM.
Reference Information
Schematic Reference
Engine Cooling Schematics
Description and Operation
Cooling Fan Description and Operation
Connector End View Reference
Component Connector End Views
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
- Verify that the following DTCs are not set: P0480, P0481, P0691, P0692, P0693, or P0694.
⇒ | If any of the DTCs are set, repair the DTC first. |
- Verify cooling fan operation using the scan tool commands listed below:
• | Fan Relay 1 ON--Both fans run at low speed. |
• | Fan Relays 2 and 3 ON--The right fan runs at high speed, the left fan is OFF. |
• | Fan Relays 1, 2, and 3 ON--Both fans run at high speed. |
Circuit/System Testing
Note: You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the series/parallel fan relay.
- Ignition ON, activate the cooling fan relay 1 with a scan tool. The fan should be OFF.
⇒ | If the fan is activated, test the left fan ground circuit terminal 3 for a short to ground. |
- Ignition OFF, disconnect the remaining fan relays.
- Connect a 30A fused jumper between the normally-open switch contact terminals 30 and 87 at the fan control relay connector in order to complete the left fan ground circuit. Leave this jumper in place for the remainder of this procedure.
- One at a time, connect a 30A fused jumper between the positive terminal at the battery and the fan voltage supply circuit terminal 87 at each relay connection and verify the appropriate fan activation.
⇒ | If the appropriate fan does not activate, test the fan voltage supply circuit for a short to ground or open/high resistance. If the circuit tests normal, test the fan ground circuit for open/high resistance. If the circuits test normal, replace the
fan. |
- Ignition ON, connect a 30A fused jumper between the relay switch voltage supply circuit terminal 30 and the fan voltage supply circuit terminal 87 at the low speed and then the high speed relay connections and verify
the appropriate fan activation.
⇒ | If the appropriate fan does not activate, test the relay switch voltage supply circuit for a short to ground or high resistance. |
- If the circuits and fans test normal, replace the relay.
Repair Instructions
Repair Verification