DTC P0010 or P0013 for Chevrolet Cobalt 2009
Diagnostic Instructions
DTC Descriptors
DTC P0010: Intake Camshaft Position (CMP) Actuator Solenoid Control Circuit
DTC P0013: Exhaust Camshaft Position (CMP) Actuator Solenoid Control Circuit
Diagnostic Fault Information
Circuit
| Short to Ground
| Open/High Resistance
| Short to Voltage
| Signal Performance
|
Intake CMP Actuator Solenoid Control
| P0010
| P0010
| P0010
| P0011
|
Intake CMP Actuator Low Reference
| --
| P0010
| --
| --
|
Exhaust CMP Actuator Solenoid Control
| P0013
| P0013
| P0013
| P0014
|
Exhaust CMP Actuator Low Reference
| --
| P0013
| --
| --
|
Circuit/System Description
The camshaft position (CMP) actuator is attached to each camshaft and is hydraulically operated in order to change the angle of the camshaft relative to crankshaft position (CKP). The CMP actuator solenoid is controlled by the control module. The control
module sends a pulse width modulated 12-volt signal to a CMP actuator solenoid. The solenoid controls the amount of engine oil flow to a CMP actuator. The CMP actuator can change the camshaft angle a maximum of 25 degrees. The control module increases
the pulse width to accomplish the desired camshaft operation.
Conditions for Running the DTC
The engine is running.
Conditions for Setting the DTC
The ECM detects an open, short to ground, or a short to voltage on the high control circuit or an open on the low reference circuit for more than 0.25 second.
Action Taken When the DTC Sets
DTCs P0010 and P0013 are Type B DTCs.
Conditions for Clearing the MIL/DTC
DTCs P0010 and P0013 are Type B DTCs.
Reference Information
Schematic Reference
Engine Controls Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Camshaft Actuator System Description
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
- Ensure the vehicle has the proper oil viscosity.
- Observe the engine oil level. The engine oil level should be within the operating range.
- Allow the engine to reach operating temperature.
- Increase the engine speed to 1,500 RPM.
- Command each CMP actuator to 25 percent. The CMP actuator angle desired parameter should match the CMP actuator actual parameter.
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Circuit/System Testing
- Ignition OFF, disconnect the CMP actuator solenoid harness connector at the CMP actuator solenoid.
- Test for less than 5 ohms between the low reference circuit terminal B and ground.
| ⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. |
- Verify that a test lamp does not illuminate between the low reference circuit terminal B and the control circuit terminal A.
| ⇒ | If the test lamp illuminates, test the control circuit for short to voltage. If the circuit tests normal, replace the ECM. |
- Remove the test lamp.
- Command the CMP Actuator Sol. ON with a scan tool. Verify the scan tool CMP Sol Ckt Short Gnd Test status is OK.
| ⇒ | If not the specified value, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
- Install a 3A fused jumper wire between the control circuit terminal A and the low reference circuit terminal B. Command the CMP Actuator Sol. ON with a scan tool. Verify the scan tool CMP Sol Ckt Short Gnd Test status is Fault.
| ⇒ | If not the specified value, test the control circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
- If all circuits test normal, test or replace the CMP actuator solenoid.
Component Testing
- Measure the resistance of each CMP actuator solenoid valve assembly. Resistance should be between 8-12 ohms.
- Connect a jumper wire between the CMP actuator low reference circuit at the solenoid and a good ground. Connect a fused jumper wire to the CMP actuator high control circuit at the solenoid. Momentarily touch the fused jumper to B+. Observe the spool
valve inside the CMP actuator. The spool valve should move from fully closed to fully opened position.
Repair Instructions