The powertrain control module (PCM) uses the generator turn on signal circuit to control the load of the generator on the engine. A high side driver in the PCM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. When the PCM turns ON the high side driver, the voltage regulator turns ON the field circuit. When the PCM turns OFF the high side driver, the voltage regulator turns OFF the field circuit.
The PCM monitors the state of the generator turn on signal circuit. The PCM should detect a low generator turn on signal circuit voltage when the key is ON and the engine is OFF, or when the charging system malfunctions. With the engine running, the PCM should detect a high generator turn on signal circuit. The PCM performs key ON and RUN tests to determine the status of the generator turn on signal circuit. During the key ON test, if the PCM detects a high generator turn on signal circuit voltage, DTC P0621 will set. DTC P0621 will also set if, during the RUN test, the PCM detects a low generator turn on signal circuit. When the DTC sets, the PCM will send a class 2 serial data message to the instrument panel cluster (IPC) to illuminate the charge indicator.
• | The ignition is ON. |
• | The engine speed is more than 1,000 RPM. |
• | The PCM detects the GEN L-Terminal active with the ignition ON. |
• | The PCM detects the GEN L-Terminal inactive with the engine operating. |
• | The above conditions are present for 6 seconds. |
• | The PCM will record the operating conditions presents when the DTC set as Failure Records data only. |
• | The IPC displays a message. |
• | The malfunction indicator lamp (MIL) will not illuminate. |
• | The Conditions for Setting the DTC are no longer present. |
• | A history DTC will clear after 40 malfunction free ignition cycles. |
• | The PCM receives the clear code command from the scan tool. |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Starting and Charging Schematics Connector End View Reference: Engine Electrical Connector End Views | |||
1 | Did you perform the Engine Electrical Diagnostic System Check? | Go to Step 2 | |
2 |
Does the scan tool indicate that DTC P0621 has passed? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Test the generator turn on signal circuit for a short or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 6 | Go to Step 4 |
4 | Inspect for poor connections at the harness connector of the powertrain control module (PCM). Refer to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 6 | Go to Step 5 |
5 | Replace the PCM. Refer to Powertrain Control Module Replacement in Engine Controls - 2.8L or Powertrain Control Module Replacement in Engine Controls - 3.5L. Did you compete the replacement? | Go to Step 6 | -- |
6 |
Does the scan tool indicate that this DTC failed this ignition? | Go to Step 2 | System OK |