Solenoid Tests
|
• | Left Front Isolation Valve |
• | Right Front Isolation Valve |
| This function allows the technician to command a selected valve solenoid On
and Off. Use the procedures below to verify proper operation of the EBCM and BPMV.
Dump Valve Solenoid Test Procedure
- Apply the parking brake fully.
- Start the engine and allow the engine to idle.
- Select the desired Dump Valve Solenoid Test on the scan tool.
- Apply the brake and maintain steady pressure on the brake pedal.
- Command the solenoid On and verify that the brake pedal drops to the floor.
Isolation Valve Solenoid Test Procedure
- Apply the parking brake fully.
- Start the engine and allow the engine to idle.
- Select the desired Isolation Valve Solenoid Test on the scan tool.
- Apply the brake with very light pressure only enough to close the brake
switch.
- Command the solenoid On and then immediately apply firm and steady pressure
to the brake pedal.
- The EBCM automatically de-energizes the solenoid after about 3 seconds.
When this occurs, verify that the brake pedal drops about 2.2 cm (1 inch).
|