The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is ON while the blower motor switch is in the OFF position or blower motor is ON when the ignition is OFF. | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
Does the blower motor operate with the ignition in the OFF position? | Go to Step 4 | Go to Step 5 | |
4 | Disconnect the IGN 3 relay. Does the blower motor turn OFF? | Go to Step 11 | Go to Step 9 |
5 |
Is the blower motor OFF? | Go to Step 6 | Go to Step 7 |
6 | Test the Low, Med 1, and the Med 2 blower motor control circuits for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 10 |
7 | Disconnect the HVAC control assembly. Is the blower motor OFF? | Go to Step 10 | Go to Step 8 |
8 | Repair the short to ground in the blower motor high control circuit. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 13 | -- |
9 | Repair the short to voltage in the blower motor supply voltage circuit. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 13 | -- |
10 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
11 | Replace the ignition 3 relay. Did you complete the replacement? | Go to Step 13 | -- |
12 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 13 | -- |
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |