Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 150-266 kPa (22-39 psi) | 740-1020 kPa (107-148 psi) | 12°C (54°F) |
19-24°C (66-75°F) | Less than 40% | 150-231 kPa (22-34 psi) | 970-1300 kPa (141-189 psi) | 10°C (50°F) |
Greater than 40% | 169-271 kPa (25-39 psi) | 960-1320 kPa (139-192 psi) | 14°C (57°F) | |
25-29°C (76-85°F) | Less than 35% | 167-248 kPa (24-36 psi) | 1210-1510 kPa (176-219 psi) | 12°C (54°F) |
35-50% | 186-254 kPa (27-37 psi) | 1220-1530 kPa (177-222 psi) | 13°C (55°F) | |
Greater than 50% | 201-266 kPa (29-39 psi) | 1220-1560 kPa (177-226 psi) | 14°C (57°F) | |
30-35°C (86-95°F) | Less than 30% | 200-276 kPa (29-40 psi) | 1410-1760 kPa (205-255 psi) | 15°C (59°F) |
30-50% | 206-270 kPa (30-39 psi) | 1430-1800 kPa (208-261 psi) | 15°C (59°F) | |
Greater than 50% | 214-261 kPa (31-38 psi) | 1450-1860 kPa (210-270 psi) | 16°C (61°F) | |
36-41°C (96-105°F) | Less than 20% | 242-316 kPa (35-46 psi) | 1640-1990 kPa (238-289 psi) | 18°C (64°F) |
20-40% | 239-296 kPa (35-43 psi) | 1660-2040 kPa (241-296 psi) | 18°C (64°F) | |
Greater than 40% | 233-275 kPa (34-40 psi) | 1700-2100 kPa (247-305 psi) | 17°C (63°F) | |
42-46°C (106-115°F) | Less than 20% | 286-347 kPa (42-50 psi) | 1880-2190 kPa (273-318 psi) | 21°C (70°F) |
Greater than 20% | 276-315 kPa (40-46 psi) | 1910-2260 kPa (277-328 psi) | 20°C (68°F) | |
47-49°C (116-120°F) | Less than 30% | 307-345 kPa (45-50 psi) | 2110-2350 kPa (306-341 psi) | 22°C (72°F) |