Tools Required
J 7872
Magnetic Base Dial Indicator Set, or equivalent
Important: This measurement procedure is intended to measure transmission or transfer case output flange runout for systems with a constant velocity (CV) joint, rubber coupling or bolt-on U-joint yoke at the transmission or transfer
case.
- Place the transmission in NEUTRAL.
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle
.
- If equipped with a CV joint, measure the transmission or transfer case output flange radial runout on the machined surface of the prop shaft front CV joint housing, as close to the flange as possible:
3.1. | Clean the surface of the prop shaft front CV joint housing just rear of the transmission or transfer case output flange. |
3.2. | Mount a dial indicator set,
J 7872
, or equivalent, and position the dial indicator to contact the prop shaft front CV joint housing as close to the transfer case output flange as possible. |
- If equipped with a rubber coupling or bolt-on U-joint yoke, measure the transfer case output flange radial runout on the machined surface of the flange pilot area:
4.1. | Mark the position of the prop shaft to the transmission or transfer case output flange. |
4.2. | Separate the propshaft from the transmission or transfer case output flange. |
4.3. | Clean the surface of the flange pilot area. |
4.4. | Mount a dial indicator set,
J 7872
, or equivalent, and position the dial indicator to contact the pilot area as close to the end of the pilot as possible. |
- Rotate the transmission or transfer case output flange by hand to locate the low spot.
- Set the dial indicator to zero on the low spot.
- Rotate the flange or shaft by hand and record the amount of radial runout.
- Compare the runout of the flange or shaft to the runout tolerance specifications guideline.
- If the transmission or transfer case output flange runout exceeds the specification, the flange or shaft requires replacement.