Draining Procedure
Important: Drain and measure as much of the refrigerant oil as possible from the removed compressor.
- Drain the oil from both the suction and discharge ports of the removed compressor into a clean, graduated container.
Rotate the compressor shaft to assist in draining the compressor.
- Measure and record the amount of oil drained from the removed compressor.
This measurement will be used during installation of the replacement compressor.
- Properly discard the used refrigerant oil.
Balancing Procedure
Important: The refrigerant oil in the A/C system must be balanced during compressor replacement.
- The Denso replacement compressor is shipped with 74 ml (2.5 oz) of refrigerant oil.
- Before installing the compressor, the refrigerant oil will have to be fully drained.
- Add back the same quantity of PAG oil as drained from the removed compressor.
Refer to the amount of refrigerant oil recorded during the compressor removal.