Removal Procedure
- Disconnect the electrical
connector from the AIR pump (4).
- Remove the outlet and inlet hoses from the AIR pump (4).
- Remove the AIR pump mounting bolts from the bracket (3).
- Remove the AIR pump (4).
Installation Procedure
- Install the AIR pump
(4) to bracket (3).
- Install the mounting bolts.
Tighten
Tighten the AIR Pump Bolts to 5.6 N·m (50 lb in).
- Connect the outlet and inlet hoses to the AIR pump (4).
- Connect the electric connector to AIR pump.
- Check the AIR system for proper operation.