Removal Procedure
- Disconnect the electrical connector.
- Remove the vacuum lines (4) from the EVAP vacuum switch (3) and the EVAP vacuum
control soleniod (1).
- Remove the EVAP vacuum switch (2) from the bracket (4).
Installation Procedure
- Install the New EVAP vacuum switch (2) to the bracket (4).
- Connect the vacuum lines (4) to the EVAP vacuum switch (3) and the EVAP vacuum
control solenoid (1).
- Connect the electrical connector.