Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Generator check: grounds, shorts, and opens | ||||
1 | Connect the ohmmeter to the slip ring and a clean metal grounding surface on the frame of the rotor to check for grounds. Does the ohmmeter read infinity? | Infinity | ||
2 | Connect the ohmmeter to both slip rings to check for opens and shorts. Does the ohmmeter read within the given specifications? | 1.7-2.1 ohms | ||
3 | Replace the rotor. Refer to Generator Disassemble . Does the ohmmeter read infinity? | Infinity | ||
4 | Connect the ohmmeter to the stator terminal and to a clean metal ground on the laminations to check for continuity. Is there continuity? | Continuity | ||
5 |
One reading should be high (open) and one low (continuity). Are the readings the same? | One high/one low | ||
6 |
Are the readings the same? | One high/one low | System OK | |
7 | Replace the rectifier bridge. Refer to Generator Disassemble . Is the repair complete? | -- | System OK | -- |
8 | Replace the stator. Refer to Generator Disassemble . Is there continuity? | -- | System OK | -- |