• | J 39775 4L60-E Jumper Harness |
• | J 39200 Digital Multimeter |
• | J 35616-A Connector Test Adapter Kit |
Important: Whenever the transmission 20-way connector is disconnected and the engine is running, multiple DTCs will set. Be sure to clear these codes when you are finished with this procedure.
Important: This procedure tests the Automatic Transmission Fluid Pressure Manual Valve Position Switch (TFP Val. Position Sw.) circuits and the Automatic Transmission Fluid Temperature (TFT) Sensor circuit. Do not use this procedure to test other Automatic Transmission circuits. Refer to 4L60-E Automatic Transmission Internal Wiring Harness check.
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
Is the resistance greater than the specified value? | 50 K ohms | ||||||||||||||||||||||
2 |
Is the resistance greater than the specified value? | 50 K ohms | ||||||||||||||||||||||
3 | Measure the resistance from terminal R to the transmission case. Is the resistance less than the specified value? | 200 ohms | ||||||||||||||||||||||
4 |
Is the resistance less than the specified value? | 200 ohms | ||||||||||||||||||||||
5 | Measure the resistance from terminal P to the transmission case. Is the resistance greater than the specified value? | 50 K ohms | ||||||||||||||||||||||
6 |
Is the resistance greater than the specified value? | 50 K ohms | ||||||||||||||||||||||
7 |
Is the resistance less than the specified value? | 200 ohms | ||||||||||||||||||||||
8 |
Is the resistance less than the specified value? | 200 ohms | ||||||||||||||||||||||
9 |
Is the resistance greater than the specified value? | 50 K ohms | ||||||||||||||||||||||
10 |
Is the resistance less than the specified value? | 200 ohms | ||||||||||||||||||||||
11 |
Is the resistance greater than the specified value? | 50 K ohms | ||||||||||||||||||||||
12 |
Important: The resistance of the TFT Sensor is temperature dependent, and therefore varies far more than any other device. Refer to Transmission Fluid Temperature Sensor in Electronic Component Description . Is the resistance within the specified range? | 3088-3942 ohms @ 20°C (68°F) 159-198 ohms @ 100°C (212°F) | ||||||||||||||||||||||
13 |
Are both resistances greater than the specified value? | 10 M ohms | No condition found. Exit the table. | |||||||||||||||||||||
14 |
Important: The resistance of the TFT Sensor is temperature dependent, and therefore varies far more than any other device. Refer to Transmission Fluid Temperature Sensor in Electronic Component Description . Is the resistance within the specified range? | 3088-3942 ohms @ 20°C (68°F) 159-198 ohms @ 100°C (212°F) | ||||||||||||||||||||||
15 |
Are both resistances greater than the specified value? | 10 M ohms | ||||||||||||||||||||||
16 | Inspect for high resistance or a short:
Did you find high resistance or a short? | -- | ||||||||||||||||||||||
17 |
Did you find an open or shorted condition? | -- | ||||||||||||||||||||||
18 | Replace the A/T Wiring Harness Assembly. Refer to TCC PWM Solenoid, TCC Solenoid, and Wiring Harness Replacement. Is the replacement complete? | -- | -- | |||||||||||||||||||||
19 | Replace the TFP Val. Position Sw. Refer to Valve Body and Pressure Switch Replacement. Is the replacement complete? | -- | -- |