Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Checks the inputs to the temperature door motor. | ||||
1 | Were you sent here from the HVAC Blower Controls System Check (C60)? | -- | Go to HVAC Blower Controls System Check (C60) | |
2 |
Is the voltage within the specified values? | 10.0-14.0V | ||
3 | Check the HVAC MiniFuse® #18 for an open circuit. Is the fuse open? | -- | ||
4 | Locate and repair an open or a high resistance in CKT 41. Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |
5 | Locate and repair a short to ground in CKT 41. Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |
6 |
Is CKT 150 continuous to ground? | -- | ||
7 | Locate and repair an open or a high resistance in CKT 150 between the temperature door motor connector and G201. Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |
8 |
Does the voltage vary within the specified values? | 1.0-12.0V | ||
9 |
Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |
10 |
Is CKT 1316 continuous to ground? | -- | ||
11 | Locate and repair a short to ground in CKT 1316. Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |
12 |
Is CKT 1316 continuous between the temperature door motor connector terminal 8 and the HVAC control head connector C1 terminal 8? | -- | ||
13 | Replace the HVAC control head. Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |
14 | Locate and repair an open or a high resistance in CKT 1316. Is the repair complete? | -- | Go to HVAC Blower Controls System Check (C60) | -- |