Blower Motor Inoperative At Med-3 (Position 4) <<C60>>
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Blower motor will operate at all
speed except Med-3 speed (Position 4).
|
1
| Were you sent here from the HVAC Blower control System
Check (C60)?
| --
|
Go to Step 2
| Go to HVAC Blower control System Check (C60)
|
2
|
- Disconnect the HVAC control head connector C2.
- Disconnect the blower motor control module connector C1.
- Connect a fused jumper wire between terminal B and terminal E
of the HVAC control head connector C2.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal C of the blower motor control
module connector C1 and a known good ground.
- Measure the available voltage at terminal C of the blower motor
control module connector C1.
Is the voltage reading within the specified range?
| 10.0 -14.0V
|
Go to Step 4
|
Go to Step 3
|
3
| Locate and repair an
open or a high resistance in CKT 73.
Is the repair complete?
| --
| Go
to HVAC Blower control System Check (C60)
| --
|
4
|
- Remove the fused jumper wire.
- Connect the HVAC control head connector C2.
- Turn the blower switch to the Med-3 position.
- Turn the ignition switch to the ON position.
- Connect the DMM between terminal C of the blower motor control
module connector C1 and a known good ground.
- Measure the available voltage at terminal C of the blower motor
control module connector C1.
Is the voltage within the specified range?
| 10.0 -14.0V
|
Go to Step
6
|
Go to Step 5
|
5
| Replace the HVAC control head.
Is the replacement complete?
| --
| Go
to HVAC Blower control System Check (C60)
| --
|
6
| Replace the blower motor control module.
Is the replacement complete?
| --
| Go
to HVAC Blower control System Check (C60)
| --
|