Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the voltage within the specified range? | 4.5 - 5.5V | ||
2 | Locate and repair an open or a high resistance in CKT 734. Is the repair complete? | -- | -- | |
3 | Use a DMM to measure the voltage between terminal A and terminal B of the inside air temperature sensor connector. Is the voltage within the specified range? | -- | ||
4 | Locate and repair an open or a high resistance in CKT 1798 between the inside air temperature sensor connector and S203. Is the repair complete? | -- | -- | |
5 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor in Automatic Air Conditioning. Is the replacement complete? | -- | -- | |
6 |
Are the DTCs cleared from memory? | -- | Recheck the System Operation. | -- |