DTC B0348 - Sun Load Temperature Sensor Circuit Open (CJ2)

Step

Action

Value(s)

Yes

No

1

  1. Disconnect the sun load temperature sensor connector.
  2. Turn the ignition switch to the RUN position.
  3. Press the AUTO mode button on the HVAC programmer module.
  4. Use a DMM to measure the voltage between terminal A of the sun load temperature sensor connector and ground.

Is the voltage within the specified range?

4.5 - 5.5V

Go to Step 3

Go to Step 2

2

Locate and repair an open or a high resistance in CKT 590.

Is the repair complete?

--

Go to Step 6

--

3

Use a DMM to measure the voltage between terminal A and terminal B of the sun load temperature sensor connector.

Is the voltage within the specified range?

4.5 - 5.5V

Go to Step 5

Go to Step 4

4

Locate and repair an open or a high resistance in CKT 61 between the sun load temperature sensor connector and S283.

Is the repair complete?

--

Go to Step 6

--

5

Replace the sun load temperature sensor. Refer to Sun Load Temperature Sensor in Automatic Air Conditioning.

Is the replacement complete?

--

Go to Step 6

--

6

  1. Press the A/C mode button on the HVAC programmer module. OR
  2. Use the scan tool to clear the DTCs from memory.

Are the DTCs cleared from memory?

--

Recheck the System Operation

--