Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Passenger's side air flow temperature does not change, no DTCs are set (CJ2). | ||||
1 |
Is the voltage within the specified range? | 10.0 - 14.0V | ||
2 | Locate and repair an open or a high resistance in CKT 41 between the instrument panel electric center and the RH electric actuator connector. Is the repair complete? | -- | Recheck System Operation | -- |
3 |
Is the voltage within the specified range? | 10.0 - 14.0V | ||
4 | Locate and repair an open or high resistance in CKT 1236. If CKT is OK, replace the HVAC programmer module. Refer to HVAC Programmer Module in Automatic Air Conditioning. Is the repair complete? | -- | Recheck System Operation | -- |
5 | Locate and repair an open or a high resistance in CKT 1798. If the CKT is OK, replace the RH electric actuator. Refer to RH Electric Actuator in Automatic Air Conditioning. Is the replacement complete? | -- | Recheck System Operation | -- |